ELISA Reader Multimode
Features:Eliza Reader for programming any Elisa Test UV, Screening, Advanced Kinetics, End point, Curve-fit.Shaking: External & Internal with programmable time & speed.Filters– 405,450,492 & 620 nm with 8-10 filter capacity.Fully Robotic compatible.Parallel Centronics, Auto curve transformation facility.Eight calculation modes which includes Facility for curve fit mode (up to 8 Std) include lin-reg, pt-pt, cubic spline, 4 parameters fit, logit-log along with Lin/Lin Lin/Log, Log/Lin, Log/Log. 12 blanking options.Onboard shaking with program time & speed.Light Source – Long life LED Source.
Technical Specifications:
Brand: TECAN, Switzerland. 
Model: Sunrise
Detection modeAbsorbance
Light sourceLED, self-calibrating
Photodetectorsilicon photodiodes
Plate type96-well microplates (including strip-well microplates)
Measurement modesendpoint, kinetic and multi-label measurements
Measurement channels8-channel
Reference channel1-channel
Measurement range0 – 4 OD (Approx.)
Resolution0.0001 OD (Approx.)
Wavelength range400 – 750 nm (Approx.).
Wavelength selectionup to 8 filters on wheel
Standard filters405, 450, 492 and 620 nm
Accuracy: Accuracy at 450 / 492 nm
0.000 – 2.000 OD or ≤ (0.5 % + 0.010 OD) typical
2.000 – 3.000 OD or ≤ (1 % + 0.010 OD) typical
Reproducibility: Precision at 450 / 492 nm
0.00 – 2.000 OD or ≤ (0.5 % + 0.005 OD)
2.000 – 3.000 OD or ≤ (1.0 % + 0.005 OD)
Linearity0.000-2.000OD or ≤1.0% & 2.000-3.000OD or ≤1.5 %
Shakinglinear shaking in 4 different modes
Computer interfaceUSB 1.1 / 2.0
Measuring time including self-check:
Single Wavelength: 15 seconds, 
Dual Wavelength: 20 seconds
Serial Interface: RS 232 C
Tested design software validated according to ISO 13485:2003 quality system of standards.
Comprehensive QC function 
Data import and export options (Excel, ASCII, ASTM)
Example files for qualitative and quantitative ELISA assays and learning tutorials. 
Additional reference channel for optimized light intensity 
Tested reliability of ≥ 100,000 plates
98/79/EC IVD-D and FDA 21 CFR part 11 for regulated environments
Dimensions: 130-145 x 345-360 x 185-200 cm (H x W x D) (Approx.)
Power requirementsSingle phase 110 ± 10 % V 50/60Hz, ISA Single phase 220 ± 10 % V 50/60Hz, 8A Single phase 230 ± 10 % V 50/60Hz, 8A
Rated Voltage & Rated Current110V: 7.0A, 220V: 3.2A, 230V: 3.1 A
Accessoriesa) Brand computer, Intel Core i7, 8GB RAM, 500 GB SSD Hard disk, DVD-RW ± Dual, Keyboard, Mouse & Pre-installed Microsoft Original Windows-10 Professional, 22” full screen monitor- 1No.
b) ELISA Plate 96-well format, high quality microplates, pure grade, non-treated surface, sterile. Free from endotoxins <0.01EU/ mL, DNase, DNA, RNASE, non-cytotoxic according to ISO 10993. Should comply with ISO11137 and AAMI guidelines.
Other Accessories:Required necessary accessories & consumables quoted above and will be supplied with equipment to install & operate the system.
Country of OriginEU-Switzerland.
Make and assemblyEU-Austria. 
Certification- Country of OriginYes
Manufacturer Authorization Letter: Yes (On Manufacturer’s letterhead pad).
Manufacturer Warranty and guaranty : Yes (On Manufacturer’s letterhead pad).
Standard Warranty and guaranty: One Year.
Extended Service Warranty: Five years (including warranty period).
Training: 1-2 days or more days training on maintenance, trouble shooting, operation, and application of equipment will be provided by us after installation and commissioning. We will train up the appointed scientists/experts/technician until ready for operation.
Packing list: Packing list from manufacturer will be provided with system.
Catalog: Manufacturer catalogue submitted in English.
Remarks (any): N/A
Price: Submitted.