Centrifuge machine (Benchtop) |
Features:Benchtop Centrifuge, from microtubes to 250mL bottles, or micro-plates.4 multiple swinging bucket rotors, 1 angle rotor and 2 micro-plate rotors are available.Innovative functions “Self-Check Function”, “Imbalance Early Detector” available.Mixed-loading available.Mixed Loading facilityEquipped with self-luminous display (VFD).Power-saving mode and Motorized lid lock.Compact body, but wide interior.Equipped with a delayed start function after setting samples.Easy spin-down with flashing function.Automatic identification of rotors by rotor sensor.Equipped with a tool less rotor.Changeable acceleration and deceleration curve. |
Technical Specifications: |
Brand | : Kubota, Japan. |
Model | : S-500T. |
System | Benchtop Centrifuge |
Swing rotor |
Max. capacity | 68X15 mL. |
Max. speed | 4,800 rpm. |
Max. RCF | 4300 Xg. |
Angle rotor |
Max. capacity | 8X50 mL conical tube. |
Max. speed | 6,000 rpm. |
Max. RCF | 5350Xg. |
Size | 44(W} X 53(D) X 32(H) cm Height with opened lid: 76 cm. |
Weight | 110V: 37 kg, 220/230V: 39 kg. |
Power consumption: calorific value | 520W, 1.9MJ/h |
| (Power-saving mode: Approx. 7W) |
Power requirements | Single phase 110 ± 10 % V 50/60Hz, ISA Single phase 220 ± 10 % V 50/60Hz, 8A Single phase 230 ± 10 % V 50/60Hz, 8A. |
Rated voltage, rated current | 110V: 7.0A, 220V: 3.2A, 230V: 3.1 A |
Use environment | Temperature: 10 – 35 [1]C |
Humidity: 30-85% |
Atmospherics pressure: 70 -106 kPa (700 -1,060 mbar) |
Conforming standard | IEC61010-2-020 |
Driving method | Direct-drive (directly connected to brushless motor) |
Control method | Inverter microprocessor control (brushless motor) |
Error display | Lid open, imbalance, over-speed, motor, rotation sensor, lid sensor, inverter, rotor sensor, imbalance sensor |
Stoppage alarm | 11 types of sounds + silent 5 levels of sound volume (including silent) |
Rotation radius settings | It can be set for each rotor. |
Centrifugation increments | 3 steps (rotation speed, time) |
Speed setting range | 200 – 6,000 rpm |
10 or 100 rpm increments |
RCF setting range | 10-5,350Xg |
10 or 100 xg increments |
Timer setting range | 1 sec to 99 hours and 59 min. |
Sec.: 1 sec. increments |
Min.: 1 min. increments |
Hour 1-hour increments |
Hold |
Temperature setting range | – |
Refrigerated | – |
Program memory | 99 channels (5 for direct invocation using the panel button) |
Acceleration / deceleration | 3 steps |
Accessories: | Rotor (Required for 1.0 – 5.0 micro-L, 15 mL and 50 mL tube)An installation Table with cabinet and rack included. |
Country of Origin | Japan. |
Make and assembly | Japan. |
Certification- Country of Origin | Yes |
Manufacturer Authorization Letter | : Yes (On Manufacturer’s letterhead pad). |
Manufacturer Warranty and guaranty | : Yes (On Manufacturer’s letterhead pad). |
Standard Warranty and guaranty | : One Year. |
Extended Service Warranty | : Five years (including warranty period). |
Training | : 1-2 days or more days training on maintenance, trouble shooting, operation, and application of equipment will be provided by us after installation and commissioning. We will train up the appointed scientists/experts/technician until ready for operation. |
Packing list | : Packing list from manufacturer will be provided with system. |
Catalog | : Manufacturer catalogue submitted in English. |
Remarks (any) | : N/A |
Price | : Submitted. |